Vulcanization autoclaves are mainly used for the vulcanization of rubber products, providing suitable pressure and temperature fields, and equipped with rapid cooling function. OLYMSPAN offers various specifications of vulcanization autoclaves with diameters ranging from 0.5 to 6.0 meters, lengths ranging from 1.0 to 50 meters, pressures ranging from 0.8 to 3.0 MPa, and temperatures ranging from 150 to 240 ℃, to meet the needs of various usage scenarios, such as rubber hoses, rollers, rubber seals, tires, etc.

5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Rubber vulcanization Autoclave

    Vulcanization autoclaves are mainly used for the vulcanization of rubber products, providing suitable pressure and temperature fields, and equipped with rapid cooling function. OLYMSPAN offers various specifications of vulcanization autoclaves with diameters ranging from 0.5 to 6.0 meters, lengths ranging from 1.0 to 50 meters, pressures ranging from 0.8 to 3.0 MPa, and temperatures ranging from 150 to 240 ℃, to meet the needs of various usage scenarios, such as rubber hoses, rollers, rubber seals, tires, etc.

    1 (44)
    1 (44)

    OLYMSPAN PHC Autoclave FAQ

    1
    Q: What are the main components of OLYMSPAN autoclave energy conservation system?
    A: The system mainly consists of four modules: ① automatic steam distribution system (automatic steam distribution of header/sub-cylinder, instead of manual valve operation); ② Waste heat storage system (introducing the residual steam in the completed autoclave into the heat storage tank and the next autoclave to be evaporated); ③ Real-time monitoring of blowdown and drainage system (automatic drainage and blowdown to avoid steam loss with condensate); ④ Zero steam discharge device (the exhaust steam is recycled after being silenced and cooled by the expander). Each module is controlled by PLC in a unified way, which can operate in linkage or be selected separately.
    2
    Q: What are the main waste links of energy consumption of autoclave? What pain points does the energy conservation system aim at?
    A: The heat distribution of autoclave curing is about 35% - 37% for heating products, 20% - 23% for heating kettle and autoclave, 3% for heat loss, 5% - 6.5% for residual steam in kettle and 30% - 33% for condensate. The combined residual heat of steam and condensate accounts for 33% - 38% of the total heat consumption - this is the part of direct emission and waste under traditional conditions. The core of the energy conservation system is to recover the waste heat and utilize the steps.
    3
    Q: What is the working principle of the waste heat storage system?
    A: Adopt the mode of "autoclave – autoclave steam pouring+tank heat storage": there is still a large amount of high-temperature and high-pressure residual steam in the autoclave after steaming and curing. The system first transfers part of the heat energy to the heat storage tank for storage, and then directly leads the residual steam in the autoclave to the next autoclave to be heated for pre-pressure rise; The heat storage tank then transfers the stored heat energy to the new kettle to complete the pre-heating. In this way, the fresh steam required by the new kettle for boiler makeup is greatly reduced.
    4
    Q: How is automatic steam distribution system better than manual operation?
    A: Generally equipped with kettle door safety interlock, pressure/temperature detection instruments, overpressure protection, venting and discharge, safety valves, etc; The interlocking logic ensures that the door cannot be opened when the kettle is under pressure, ensuring operational safety (specific configuration subject to the scope of supply).
    5
    Q: What factors affect the steam consumption of the autoclave? How to save more energy?
    A: Traditional manual steam distribution relies on workers' experience. Unstable steam flow rate easily causes large temperature difference between the upper and lower parts of the kettle, accumulated condensate, and immature or over-steamed products. The automatic steam distribution system automatically regulates the opening of the valve according to the preset temperature and pressure curve to realize automatic pressure rise, constant temperature and pressure relief. The temperature difference of the temperature field in the kettle can be controlled within ± 2 ℃ (typical value in the industry), which not only ensures the maintenance consistency, improves the strength stability of the product, but also avoids the additional energy consumption caused by the extension of the pressure maintaining time.
    6
    Q: Why can the real-time monitoring sewage drainage system save energy?
    A: The traditional autoclave mostly adopts manual blowdown and floating ball drainage. Workers often do not drain timely due to poor working conditions, resulting in ponding in the autoclave: the ponding will block the steam flow, reduce the heat transfer efficiency, cause steam waste, the product is not easy to be cooked, and the autoclave body is easy to be deformed due to uneven heating and cooling. The automatic blowdown device of OLYMSPAN uses the liquid level electrode to control the electric valve to automatically drain water, open the valve at high liquid level and close the valve at low liquid level - the condensate water is discharged in time and the steam is not leaked, which solves the three problems of energy consumption, quality and equipment life at one time. The high-efficiency and energy-saving autoclave is also equipped with a proprietary impurity removal structure (basket filter two-way design) to protect the drain valve and maintain under no pressure.
    7
    Q: How much energy consumption can be reduced after installation of energy-saving system?
    A: The following levels can be referred to for the public data of the industry: 15% - 25% energy can be saved only by multilayer aluminum silicate insulation of the kettle body; The energy conservation index (the ratio of the steam supplied by the accumulator to the fresh steam consumption in the booster) can reach over 20% after the residual steam recovery (steam reversing) system is installed.
    8
    Q: How is "Zero Steam Discharge" achieved? Will it affect emissions compliance?
    A: The low-pressure residual steam after steaming and curing is no longer directly discharged to the air, but after two-stage utilization, the remaining exhaust steam enters the expansion vessel for sound attenuation and cooling, and the condensed water is centrally recycled to the sedimentation tank, and recycled or discharged as the batching water and pulping water after being treated to meet the standard. In this way, the problem of "white steam" and noise disturbance in the plant area is eliminated, and the environmental protection emission requirements are met, so as to realize "zero direct discharge to the outside and full circulation to the inside".
    9
    Q: Where can recovered condensate and heat be used?
    A: High-temperature condensate is flashed out from the flash drum to produce secondary steam, which can be used to preheat the soft water of the boiler; The hot water after flashing can also be used for heating the still room, the pre-curing room in front of the kettle (40 – 50 ℃) and the rebar drying kiln (50 – 60 ℃), or heating the domestic water, making full use of the waste heat without consuming the fresh steam, so as to further dilute the unit product cost.
    10
    Q: Can the old autoclave (another brand) be equipped with this energy saving system? Is the transformation troublesome?
    A: Yes. The energy conservation system belongs to the complete transformation of pipeline, valve, heat storage tank and control level, and generally does not need to replace the kettle body. Typical reconstruction contents include: installation of automatic steam distribution valve group, steam reversing pipeline and interlocking valve, heat storage tank, automatic drainage and blowdown device and PLC control cabinet. The transformation period depends on the number of kettles and the on-site pipeline layout, and it usually requires several days to two weeks of shutdown and installation. OLYMSPAN can send technicians to carry out site survey and issue targeted plan.
    11
    Q: Will energy conservation system bring potential safety hazards? Are maintenance and operation complex?
    A: On the contrary, safety is improved. The system is equipped with multiple interlocks such as pressure, temperature and valve position. The process of steam reversing and pressure relief is automatically executed according to the program to avoid manual misoperation; Safety interlocking procedures are set between valves to prevent accidents such as opening with pressure. Instead, the operation is simpler: the workers only need to set the process curve and load it out of the kettle. The whole process of heating, constant temperature, steam reversing, pressure relief and blowdown is automatically completed. The data is traceable and can be remotely monitored. Routine maintenance mainly includes regular inspection of drain valves, filters (the impurity removal structure supports one-way maintenance and one-way online operation without pressure operation) and valve seals. The maintenance amount is lower than that of traditional manual system.
    Feel free to contact us with any questions you have.
    Please fill out the contact form below if you would like to receive more information about our company or our product range. 
    Contact Our Email or Call Us
    Get in touch with us
    Related Products
    OLYMSPAN originated in 1988 and is located in Henglin Town, Changzhou City, Jiangsu Province, China.
    Contact Us
    Contact: Timi Shen
    Contact number: +86-18118010110
    WhatsApp: +86-18118010110
    Address: No.29, Changhong East Road, Changzhou City, Jiangsu Province, China
    Contact us
    wechat
    email
    whatsapp
    messenger
    Contact customer service
    Contact us
    wechat
    email
    whatsapp
    messenger
    cancel
    Customer service